9. In the command line in your Virtualization Manager console, type the following:
restore.sh/ .bat backupDB.tar.datetime.4.0.x.x.tar
10. Restart the management server.
11. Power cycle the node that was originally the single node management server.
12. Run the VI script to fix DHCP.
13. Login to your management server. Use the same password for your Enterprise
Edition Virtualization Manager that you used for your Single Server Edition, and
log in.
Reference Number: 2572/2700/2701
ONLINE HELP DOES NOT REFLECT CHANGES IN RELEASE 3.7.0.
This issue, which originally occurred in 3.7.0, has been resolved in Release 4.0.0.
Reference Number: 2760
SSE RAID CONSIDERATIONS, REV 3.
The following information has been added to Chapter 2 of Virtualization Manager
Administrator Guide:
When using RAID on SSE, you should consider the layout of the RAID set prior to
SSE installation. If you are going to use RAID to configure your physical storage
prior to VI installation, you should configure one physical volume to be excluded
from the RAID set and it will be used for the Virtual Iron install. You should create
another volume(s) using the remaining storage to store virtual/logical disks for use
by Virtual Servers.
During the installation process, the SSE installer will clear the all disk data on the
boot volume of the physical server; so is not recommended to store logical disks on
that volume. Logical disks created on the boot volume can be saved, but it requires
that you export the drives prior to the re-install process. This is a time consuming
process. Therefore, if you have multiple physical volumes on your node, combining
them into one single large RAID'ed volume is not an optimal practice.
A better approach is to use one physical volume for the Virtual Iron software and
then create separate volumes to be used for logical disks. We recommend at least
36 GB for this volume. Then you can configure the remaining physical volumes for
logical disks.
Here's an example. If you have four 250 GB disks in your system, you should not
create one large 1,000 GB volume. Instead, use one 250 GB volume for the boot/
install disk, and then you can create one 750 GB RAID-set volume to be used for
storing logical disks.
Reference Number: 3031
NBD FILE .ISO EXTENSION MUST BE LOWER CASE
For iso files to appear in the VS Configuration & Boot Options > Network (image)
Boot menu, the .iso extension must be in lower case letters.
Reference Number: 3049