3.4.16.57 MEM6004 : "Memory device status is critical. Memory device location: <location>,
Possible memory module event cause: <cause>."
When event is generated, message will have the following substitutions:
<location> = "DIMM_A1"
<cause> = " Single bit error logging disabled"
3.4.16.58 MEM6005 : "Memory device has failed. Memory device location: <location>,
Possible memory module event cause: <cause>."
When event is generated, message will have the following substitutions:
<location> = "DIMM_A1"
<cause> = " Single bit error logging disabled"
3.4.16.59 MEM7000 : "The memory riser mismatch was corrected."
3.4.16.60 MEM7002 : "A hardware mismatch detected for memory riser."
3.4.16.61 MEM8000 : "Correctable memory error logging disabled for a memory device at
location <location>."
When event is generated, message will have the following substitutions:
<location> = "DIMM1"
3.4.16.62 MEM8001 : "Persistent correctable memory error logging enabled for a memory
device at location <location>."
When event is generated, message will have the following substitutions:
<location> = "DIMM1"
3.4.16.63 MEM9000 : "Memory interconnect degraded."
3.4.16.64 MEM9001 : "Memory interconnect is functioning normally."
3.4.16.65 MEM9002 : "Intel QPI interconnect <QPI link number> has a correctable error."
When event is generated, message will have the following substitutions:
<QPI link number> = "1"
3.4.16.66 MEM9003 : "Intel SMI 2 Memory interconnect <link number> has a correctable
error."
When event is generated, message will have the following substitutions:
<link number> = "1"
3.4.16.67 MEM9004 : "Intel QPI interconnect <QPI link number> has degraded."
When event is generated, message will have the following substitutions: